I/O Controllers | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I/O PLEXER |
|||||||||||||||||||||||||||||
![]()
|
Accepts Mix of Analog and Digital I/O Modules: Provides
remote analog and/or digital I/O over Ethernet or
RS-232/422/485 serial communications links at baud rates up to 38.4KB. RS-232
port includes control signals. duTec instructions are 163% compatible with
Optomux protocol. Includes Local Control Function Blocks (LCFs) for remote
stand-alone controller operation. Software and push button selection of address
and baud rate. Sockets for any mix of 16 analog or digital I/O modules. Optional
16, 32, 48 digital I/O line expansion (IOP-AD/3+). Built into a stainless
steel case with a UL/CSA 90-265 Vac power supply.
Data sheet.
Now includes a $1000 HMI Package (WIZCON for Windows & Internet, Version 7.5) from eMation (by request). Package included up to 20 points, can be upgraded to handle many more points. |
||||||||||||||||||||||||||||
I/O PLEXER Repeater |
|||||||||||||||||||||||||||||
![]() |
Accepts Mix of Analog and Digital I/O Modules: A bi-directional analog and digital signal repeater. Used in pairs (no external computer required) an input at one unit is an output at the other. Operates over RS-232/422/485 serial communications links at baud rates up to 38.4KB. Modem control signals provided for dedicated RS-232 communications. Software and push-button selection of address and baud rate. Sockets for any mix of 16 analog or digital I/O modules. Optional 16, 32, 48 digital I/O modules. Optional 16, 32, 48 digital I/O line expansion. Built into a stainless steel case with a UL/CSA 120 Vac power supply. Data sheet. | ||||||||||||||||||||||||||||
BASIC I/O |
|||||||||||||||||||||||||||||
|
Accepts Mix of Analog and Digital I/O Modules: Provides
remote analog and/or digital I/O over
ethernet or RS-422/485 serial communications
links at baud rates up to 38.4KB. duTec instructions are
163% compatible with Optomux
protocol. AD versions include Local Control Function Blocks (LCFs) for remote
stand-alone controller operation. Software and push button selection of address
and baud rate. Available in 4, 8, or 16 module versions. Requires external
5 Vdc power supply. Data sheet.
Now includes a $1000 HMI Package (WIZCON for Windows & Internet, Version 7.5) from eMation (by request). Package included up to 20 points, can be upgraded to handle many more points. |
||||||||||||||||||||||||||||
I/O Modules
|
|||||||||||||||||||||||||||||
![]() |
Analog - Each analog 12 bit module contains its own
independent transformer-isolated power supply. This provides complete electrical
isolation: module-to-module as well as module-to-logic. Wide variety of modules
includes Analog Input; voltage, current, frequency and temperature; and Analog
Output; voltage and current. Click here for
data sheet which lists each
module type, with detailed specifications.
Digital - Each module has 4000V photo isolation, UL recognition and CSA certification. Varieties include Digital Input/Output voltage and contact, power supply and I/O test module. Click here for data sheet which lists each module type, with detailed specifications. |
||||||||||||||||||||||||||||
Software
|
|||||||||||||||||||||||||||||
duTec Software
|
HSW-LCF - Local Control Function
Block Program Generator: A Windows based Visual BASIC program to configure
and download LCF Block programs for remote stand-alone controller and logic
operations. Unrestricted site license. Factory support provided to registered
purchaser. Data sheet. Download demo version here.
HSW-DDE - duTecDDE Driver: Server operates with any DDE compliant
Windows operating system (Windows 95, 98 & NT). Also supports duTec
Speak-On-Event (SOE) in which remote events (analog or digital) can initiate
a SCADA scan. Unrestricted site license.
Data sheet.
HSW-DDEL - duTecDDE Light Driver - supports a single communication
node, up to 64 I/O modules.
|
||||||||||||||||||||||||||||
Communication |
|||||||||||||||||||||||||||||
BAUDMASTER | |||||||||||||||||||||||||||||
![]() |
BAUDMASTER: Isolated Serial Converter Provides isolation for serial communication circuits; converts RS-232 to RS-422/485 and automatically controls RS-485 transmitter-enable independent of baud rate, to 115KB without software or jumpers. Stainless steel enclosure. Operates from 9-12Vac-dc wall plug adapter. To meet European CE import requirements the BAUDMASTER CE version must be powered by duTec wall-plug adapter with included ferrite rings. Data sheet | ||||||||||||||||||||||||||||
ETHERPLEXER |
|||||||||||||||||||||||||||||
|
Now another choice of communication is available to users of our I/O products. With the addition of an Ethernet option for our I/O PLEXER, and BASIC I/O products, your communication, monitoring and control options include your LAN, or Internet. This option may be purchased with a new system, or added to an existing one. Data sheet | ||||||||||||||||||||||||||||
[ Home ] [ Products ] [ Data Sheets ] [ Support ] [ FAQ ] [ Sales Offices ] [ Request Catalog ] [ Contact duTec ]
© Copyright 1996-2001, duTec. All rights
reserved.
"Optomux" is a trademark of OPTO22.
|